: - 9:00-18:00

:

+


   


   
1 USD = 60.8583
   11  -:

OK  


body

Haiwell: S04XA,

: S04XA
: 133 USD
:
  1 
 
/: 2AI/2AO
: 1xRS485
RS-485 - ( Mdbus RTU )

S04XA

(AI)2
(AO)
1xRS485
12

DC24V -15%~+20%
2.4VA
MAX 20A 1.5 @24 VDC
10
2 A, 250 V
,

70*95*82
()266
()353

/

: 0 ~ + 55 °C; : - 25 ~ + 70 °C : 5 ~ 95% RH,

10~57 0.075mm, 57 ~ 150 1G,X, Y, Z 10

15G, 11 , X, Y, Z 6

AC EFT: 2500V, surge: 2500V, DC EFT: 2500V, surge: 1000V

AC PE 1500 VAC, 1

DC PE 500 VAC, 1

AC and PE 500 VDC >=5M

PE 500 VDC

70*95*82

 S04XA

S04XA

(AI)

-10 ~ +10 0 ~ +10 0 ~ +5 1 ~ +5 0 ~ 20A 4A ~ 20A
5 2.5 1.25 1.25 5A 5A
6M 250
13 30
5 4
12
0.2%
( )
24VDC 20%,100()

(AI)

    (AI)

(AO)

-10 ~ +10 0 ~ +10 0 ~ +5 1 ~ +5 0 ~ 20 4~20
5 2.5 1.25 1.25 5 A 5 A
1 K @ 10 >= 500 @ 5 <= 500
10
3
12
0.2%
( )
24VDC 20%,100 ()

(AO)

    (AO)

CRNumber FunctionDeclare
S04XA
00H(Readonly) Thelowbyteisthemodulecode,andthehighbyteisthemoduleversionnumber.
01H Communicationaddress
02H Communicationprotocol:Thelow4-bitofthelowbyte:0-N,8,2ForRTU,1-E,8,1ForRTU,
2-O,8,1ForRTU,3-N,7,2ForASCII,4-E,7,1ForASCII,5-O,7,1ForASCII,6-N,8,
1ForRTU
Thehigh4-bitofthelowbyte:02400,14800,29600,319200,438400,
557600,6-115200
03H~06H Extendmodulename
07H~08H DefaultIPaddress:192.168.1.111
09~0AH(Readonly) Reserve
0BH Highbytesubnetmask(b3~b0,1indicates255,0indicates0,forexamplesubnetmask
255.255.255.0,b3~b0=1110),lowbytereserved
0CH~0EH(Readonly) Reserve
0FH(Readonly) Errorcode:0-Normal,1-Illegalfirmwareidentity,2-Incompletefirmware,3-Systemdataaccessexception,4-Noexternal24Vpowersupply
10H(Readonly) Theinputvalueofchannel1
11H(Readonly) Theinputvalueofchannel2
12H Thesignaltypeofinputchannel1,note2
13H Thesignaltypeofinputchannel2,note2
14H Usetheengineeringvaluemark,note6
15H Thelowerlimitinengineeringvalueofinputchannel1
16H Thelowerlimitinengineeringvalueofinputchannel2
17H Theupperlimitinengineeringvalueofinputchannel1
18H Theupperlimitinengineeringvalueofinputchannel2
19H Thesamplingfrequencyofinputchannel1
1AH Thesamplingfrequencyofinputchannel2
1BH zeropointcorrectionvalueofinputchannel1
1CH zeropointcorrectionvalueofinputchannel2
1DH(Readonly) Channel1~2inputdisconnectionalarm,note5
1EH Theoutputvalueofoutputchannel
1FH Theoutputvalueofchannel2
20H Thesignaltypeofoutputchannel1,note2
21H Thesignaltypeofoutputchannel2,note2
22H Usetheengineeringvaluemark,note6
23H Thelowerlimitinengineeringvalueofoutputchannel1
24H Thelowerlimitinengineeringvalueofoutputchannel2
25H Theupperlimitinengineeringvalueofoutputchannel1
26H Theupperlimitinengineeringvalueofoutputchannel2
27H Thepower-offoutputmark,note8
28H Thepower-offoutputvalueofoutputchannel1
29H Thepower-offoutputvalueofoutputchannel2
2AH(Readonly) Theoutputchannelindicator,note7
2BH~2FH(Readonly) Reserve

1. Sampling frequency:0 - 2 times、1 - 4 times、2 - 8 times、3 - 16 times、4 - 32 times、5 - 64 times、6 - 128 times、7 - 256 times

2. Signal type:0 - [4,20]mA、1 - [0,20]mA 、2 - [1,5]V、3 - [0,5]V、4 - [0,10]V、5 - [-10,10]V

3. The signal type of thermal resistance:0 - Pt100、1 - Pt1000、2 - Cu50、3 - Cu100

4. The signal type of thermocouple:0 - S、1 - K、2 - T、3 - E、4 - J、5 - B、6 - N、7 - R、8 Wre3/25、9- Wre5/26、10 - [0,20]mV、11 - [0,50]mV、12 - [0,100]mV

5. Disconnection alarm:Each bit indicates 1 channel, 0-normal, 1-disconnection

6. Use the engineering value mark:Each bit indicates 1 channel, 0-No, 1-Yes

7. Channel indicator status:Each bit indicates 1 channel, 0-off, 1-on

8. Power-off output mark:Each bit indicates 1 channel, 0-No, 1-Yes

9. The output flag while power supply lost: each bits signify 1 Channel ,0-No,1-Yes

S04XA

AI/AO Extension Module (eng) 13/06/2017 [pdf - 0.4MB]
HaiwellHappy V2.2.4. Haiwell PLC 05/06/2017 [ rar - 27MB]
PLC Haiwell (eng) 05/06/2017 [pdf - 8.6MB]
HaiwellHappy (eng) 20/04/2017 [chm, 4.92MB]